ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 19 (1996), S. 69-79 
    ISSN: 0935-6304
    Keywords: Large volume injection ; PTV injector ; Water analysis ; River sediment ; Pesticides ; Polycyclic aromatic hydrocarbons (PAHs) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Temperature programmable (PTV) injectors with packed widebore (ca. 3.5 mm i.d.) liners are used for large volume injection in capillary gas chromatography with the aim to simplify and/or improve off-line sample pretreatment proecdures. A simple procedure for optimization of large volume PTV injection is described. The system performance, i.e. linearity and repeatability, is evaluated for polar nitrogen/phosphorus containing pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water extracts as well as for polycyclic aromatic hydrocarbons (PAHs) in river sediment (PTV-GC-MS).
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 413-418 
    ISSN: 0935-6304
    Keywords: On-line extraction-GC ; Phase-switching ; Open-tubular traps ; Stationary phase swelling ; Large volume injection ; PTV ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The applicability of open-tubular trapping columns for on-line extraction-capillary GC analysis is evaluated. The extraction step involves sorption of the analytes from water into the stationary phase of an open-tubular column, removal of the water by purging the trap with nitrogen, and desorption of the analytes with an organic solvent. The effect of swelling of the stationary phase with organic solvents on the retention power of the trap is studied. When using pentane or hexane as swelling agent breakthrough volumes of at least 10 ml can easily be obtained for non-polar compounds. For a number of medium polarity compounds breakthrough volumes of 5 ml can be achieved when chloroform is used as the swelling agent. The required drying time is less than 1 minute. Quantitative desorption requires only 75 μl of organic solvent. Solvent elimination prior to transfer to the GC column is carried out using a PTV injector and a multidimensional GC system. The system is applied for the analyses of river water, urine, and serum samples.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 16 (1993), S. 459-463 
    ISSN: 0935-6304
    Keywords: LC-GC ; Aqueous samples ; Large volume injection ; PTV injector ; Solid-phase extraction ; Thermal desorption ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A system is described that allows the introduction of large volumes of water samples in capillary GC. Water elimination is carried out in the solvent split mode in a PTV injector with a packed liner. Two ways of separating water and analytes, i.e. evaporative and non-evaporative (solid-phase extraction), are compared. Sampling in the solid-phase extraction mode is favorable both in terms of recovery as well as with regard to sampling time. Quantitative recovery is obtained for priority pollutants ranging in volatility from dimethyl-phenol to phenanthrene. Losses occur for more volatile compounds, but even for these compounds the repeatability of the recoveries remains acceptable. With the system described here, water samples up to at least 1 ml of water can be directly analyzed. The detection limits are in the sub-ppb range.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 19-27 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Large volume injection ; PTV injectors ; PTV splitless injection ; PTV solvent split injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Temperature programmable injectors with liner diameters ranging from 1 to 3.5 mm are evaluated and compared for solvent split injection of large volumes in capillary gas chromatography. The liner dimensions determine whether a large sample volume can be introduced rapidly or has to be introduced in a speed controlled manner. The effect of the injection technique used on the recovery of n-alkanes is evaluated. Furthermore the influence of the liner diameter on the occurrence of thermal degradation during splitless transfer to the analytical column is studied. Guidelines are given for the selection of the PTV liner internal diameter best suited for specific applications.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 18 (1995), S. 124-128 
    ISSN: 0935-6304
    Keywords: Large volume injection ; PTV injector ; PTV solvent split injection ; Packed inserts ; Thermal degradation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...