ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Analytical Chemistry and Spectroscopy  (6)
  • Supercritical fluid chromatography  (2)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Chromatographia 25 (1988), S. 775-780 
    ISSN: 1612-1112
    Schlagwort(e): Supercritical fluid chromatography ; Mixed mobile phases ; Capillary and packed columns ; Antibiotics
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary The separation of polar thermally labile solutes is one of the potentially most rewarding fields of SFC application. A presupposition for such applications is, however, mobile phases having relatively high solvent strengths. A promising approach to achieve this is the use of mobile phases consisting of carbon dioxide with a polar additive. In this work, the chromatographic effects of different concentrations of an additive, isopropanol, in carbon dioxide have been studied on capillary and packed columns. A series of antibiotics was used as test substances. Best results were obtained with carbon dioxide/8% isopropanol as mobile phase on a capillary column coated with a cyanopropyl-substituted polysiloxane stationary phase.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1612-1112
    Schlagwort(e): Ligand exchange chromatography ; Supercritical fluid chromatography ; Selective stationary phases ; Argentation open tubular columns ; Poly(methylpropylthiol)siloxanes
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie
    Notizen: Summary Poly(methyl-3-propylthiol)siloxane has been evaluated for use as stationary phase in open tubular columns for gas and supercritical fluid chromatography. Immobilization of the stationary phase was achieved by crosslinking with 2,4,6-trichloro-1,3,5-triazine. The poly(methyl-3-propylthiol)siloxane stationary phase film was in situ oxidized to the disulphide and sulphonic acid forms and both have been evaluated for use in supercritical fluid chromatography. Good selectivity towards polar polycyclic aromatic compounds has been shown. All the modified forms of the stationary phase were loaded with silver ions and were evaluated with regard to ligand exchange chromatography using supercritical fluid carbon dioxide as a mobile phase. The utility of the stationary phase, having sulphonic acid groups loaded with silver ions, has been demonstrated by separation of fatty acid methyl esters according to their unsaturation.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 632-650 
    ISSN: 0935-6304
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 8 (1985), S. 734-740 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography-mass spectrometry ; Capillary columns ; Stationary phases ; Silicones ; Thermal degradation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The applicability of capillary columns for gas chromatography is often limited by stationary phase degradation at elevated temperatures. In order to achieve a better understanding of column thermostability, column bleed products have been analyzed qualitatively by gas chromatography-mass spectrometry (GC-MS). Three silicone stationary phases were studied: SE-52, SE-54, and OV-1701. Each of these was immobilized in the columns. The proportion of cyclics containing diphenyl in column bleed from SE-52 reflected to a large extent the composition of the polymer, while for SE-54 the proportion of such cyclics was unexpectedly high. The polar moiety of OV-1701, the cyanopropyl(phenyl)siloxy unit, was found to exert a highly destabilizing effect on the polymer, and the thermal degradation products consisted mainly of cyclosiloxanes containing this unit.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 232-244 
    ISSN: 0935-6304
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 23 (2000), S. 619-627 
    ISSN: 0935-6304
    Schlagwort(e): Enantiomer separation ; mixed chiral selectors ; modified cyclodextrins ; gas chromatography ; PCB ; o,p´-DDD ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Columns containing different types of cyclodextrin derivatives have been evaluated for chiral gas chromatographic separation of atropisomeric PCBs, o,p´-DDT and o,p´-DDD. Separation was attempted on columns containing mixed chiral selectors, and the performance of two closely related selectors was also examined. The cyclodextrins were: permethylated-β-CD (PM-β-CD), heptakis(2,3-di-O-methyl-6-O-tert-butyldimethylsilyl)-β-CD (2,3-M-6-TBDMS-β-CD), heptakis(2,3-di-O-methyl-6-O-tert-hexyldimethylsilyl)-β-CD (2,3-M-6-THDMS-β-CD), and heptakis(2,3-di-O-ethyl-6-O-tert-hexyldimethylsilyl)-β-cyclodextrin (2,3-E-6-THDMS-β-CD). The cyclodextrins were dissolved in OV-1701 or in a dimethylsiloxane/silarylene copolymer containing 5% phenyl in the backbone. The application of mixed chiral selectors led to improved separations, however; at most eleven PCB congeners were separated on a single column. Chiral resolution of o,p´-DDD was achieved. The use of a dimethylsiloxane/silarylene copolymer as a matrix for the cyclodextrins is a promising approach. With such a matrix, blocking of the CD cavities by silicone substituent groups can be avoided, and a reasonable CD solubility can be provided. The selectivity of heptakis(2,3-di-O-ethyl-6-O-tert-hexyldimethylsilyl)-β-CD and heptakis(2,3-di-O-methyl-6-O-tert-hexyldimethylsilyl)-β-CD was quite different, the former selector could separate four congeners, while the latter separated ten congeners.
    Zusätzliches Material: 5 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 95-100 
    ISSN: 0935-6304
    Schlagwort(e): Thin-layer chromatography, HPTLC ; Reversed phase mode ; Modification of commercially available plates ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The condition for in situ chemical modification of commercially available thin-layer plates have been varied and the influence thereof upon reversed phase plate properties has been studied. The reaction variables studied were: average silica pore size, silica water content, use of tri- or monochlorosilanes as modifiers, reaction temperature, and addition of base. Coverage and activity of residual silanol groups was studied on modified plates.Desired plate properties are high speed of development in aqueous solvents and low content of active residual silanol groups. Under the conditions tested, the lowest amount of residual silanols was achieved at the expence of the speed of development in aqueous media and vice versa.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Microcolumn Separations 5 (1993), S. 141-147 
    ISSN: 1040-7685
    Schlagwort(e): light scattering detection ; supercritical fluid chromatography ; packed microcolumns ; argentation chromatography ; triacylglycerols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Packed capillary columns provide excellent separation of neutral lipids by supercritical fluid chromatography. For these separations, it is necessary to add a polar modifier to the mobile phase; hitherto, a detector suitable for quantitative analysis has been lacking. For this purpose, a miniaturized evaporative light scattering detector for combination with packed microcolumns in supercritical fluid chromatography has been developed. Since the detector response is dependent on the mobile phase flow rate, a drop in response was found at flow rates above 16 mL min-1 of expanded mobile phase. However, below this flow rate, there was a region of relatively constant response. In this region, quantitative analysis could also be successfully performed when the pressure and/or the temperature of the separation were programmed. The detection limit was lower than 6 ng. With pressure programming, the relative standard deviation in peak area was less then 4%. Minor peaks gave higher RSD values.Further, it is demonstrated that argentation SFC of triacylglycerols provides separation according to chain length as well as to the degree of unsaturation.
    Zusätzliches Material: 7 Ill.
    Materialart: Digitale Medien
    Standort Signatur Erwartet Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...