Summary A simple and versatile calibration method for the infrared spectrometric trace analysis of gases and vapours is described. A dynamically operating set-up consisting of a capillary dosage system and a dilution unit with a set of micro-orifices was used for producing exactly known small volume fractions of trace constituents in gas mixtures. The infrared absorption measurements were performed using a Fourier transform spectrometer equipped with a long-path gas cell. Absorption coefficients of selected vibrational-rotational bands obtained by a linear least-squares fit around the threshold limit values are reported for NH3, SO2, CCl4 and 1,4-dioxane as examples of trace constituents in air.
Notizen:
Zusammenfassung Ein vielseitig einsetzbares einfaches Kalibrierverfahren für die infrarotspektrometrische Spurenanalytik von Gasen und Dämpfen wird beschrieben. Zur Realisierung genau bekannter kleiner Volumenanteile von Spurenkomponenten in Gasmischungen diente eine nach dem dynamischen Prinzip arbeitende Apparatur, bestehend aus einem Capillardosierer und einer Verdünnungseinheit mit Mikroblenden. Zur Messung der Infrarotabsorption wurde ein Fourier-Transform-Spektrometer mit Langweggasküvette verwendet. Für NH3, SO2, CCl4 und 1,4-Dioxan als Beispiele für Spurenkomponenten in Luft werden die mit Hilfe einer linearen Ausgleichsrechnung im Bereich der MAK-Werte erhaltenen Absorptionskoeffizienten ausgewählter Schwingungs-Rotationsbanden angegeben.