ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
  • 1
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Environmental science & technology 21 (1987), S. 664-670 
    ISSN: 1520-5851
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    s.l. : American Chemical Society
    Journal of the American Chemical Society 115 (1993), S. 2982-2983 
    ISSN: 1520-5126
    Source: ACS Legacy Archives
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Cambridge : Cambridge University Press
    The @China quarterly 46 (1971), S. 377-378 
    ISSN: 0305-7410
    Source: Cambridge Journals Digital Archives
    Topics: Linguistics and Literary Studies , History , Political Science , Sociology , Economics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 9 (1999), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Four commercially available low-volatile organic compound (VOC) latex paints were evaluated as substitutes for conventional latex paints by assessing both their emission characteristics and their performance as coatings. Bulk analysis indicated that the VOC contents of all four paints tested were considerably lower than those of conventional latex paints. Low VOC emissions were confirmed by small chamber emission tests. However, significant emissions of several aldehydes, especially formaldehyde which is a hazardous air pollutant, were detected in emissions from two of the four paints. American Society for Testing and Materials (ASTM) methods were used to evaluate the hiding power, scrub resistance, washability, dry to touch and yellowness index. The results indicated that one of the four low-VOC paints tested showed performance equivalent or superior to that of a conventional latex paint used as control. It was concluded that low-VOC latex paint can be a viable option to replace conventional latex paints for prevention of indoor air pollution. However, paints marketed as “low-VOC” may still have significant emissions of some individual VOCs, and some may not have performance characteristics matching those of conventional latex paints.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 4 (1994), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Full-scale residential house tests were conducted to evaluate the effects of organic emissions from a wood finishing product – wood stain – on indoor air quality (IAQ). The test house concentrations of three alkane species, nonane, decane, and undecane, were measured as a function of time after the application of the wood stain. It was found that the test house concentrations can be simulated by an integrated IAQ model which takes into consideration source, sink and ventilation effects. The alkane emissions were controlled by an evaporation-like process. Data analysis indicated that there were significant sink effects in the test house. Different sink strengths were estimated by the model for the three alkane species. An inverse relationship between the test house sink strength and the alkane volatility was found.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 8 (1998), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Small environmental chamber tests were conducted to characterize the emissions of a toxic chemical compound – methyl ethyl ketoxime (MEKO) – from three different alkyd paints. It was found that MEKO emissions occurred almost immediately after each alkyd paint was applied to a pine board. Due to the fast emission pattern, more than 90% of the MEKO emitted was released within 10 hours after painting. The peak concentrations of MEKO in chamber air correlated well with the MEKO content in the paint. Material balance showed that good recovery (more than 68%) was achieved between the MEKO applied with the paint and the MEKO emitted. The chamber data were simulated by a first order decay emission model assuming the MEKO emissions were mostly gas-phase mass transfer controlled. The model was used to predict indoor MEKO concentrations during and after painting in a test house. It was found that the predicted test house MEKO concentrations during and after the painting exceeded a suggested indoor exposure limit of 0.1 mg/m3 for all three paints. The predicted MEKO concentrations exceeded even the lower limit of a suggested sensory irritation range of 4 to 18 mg/m3 with two of the three paints tested. The model was also used to evaluate and demonstrate the effectiveness of risk reduction options including selection of lower MEKO paints and higher ventilation during painting.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 2 (1992), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: The emission charaaaistics of four organic compounds (non-ane, decam, undecane, and 1, 2, 4-trimethylbenzene)from wood stain have been measured in an environmental chamber It was found that the emission patterns of the four organic compounds can be described by a two-phase model. Phase 1 represents the period when the wood stain is relatively wet. Phase 2 is when the wood stain becomes relatively dry. The changes of emission mechanisms between the two phases were reflcted by the significantly different emission rate canstants measured during the two periods and the relationship between the relative rate constant, the relative vapor pressure, and the relative diffusivity. A double-exponential model was established that can be used to predict the relative emission rates of the four organic compounds fiom the wood stain.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Indoor air 7 (1997), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract The effects of two substrates - a stainless steel plate and a gypsum board - on the volatile organic compound (VOC) emissions from a latex paint were evaluated by environmental chamber tests. It was found that the amount of VOCs emitted from the painted stainless steel was 2 to 10 times more than that from the painted gypsum board during the 2-week test period. The dominant chemical species emitted were also different between the two substrates. Data analysis indicated that most VOC emissions from the painted stainless steel occurred in the first 100 h via a fast, evaporation-like process. On the other hand, the majority of the gypsum board VOCs were emitted in a later stage via a slow, diffusion-controlled process. There were measurable emissions of VOCs 11 months after paint application on the gypsum board. It is suggested that, instead of the routinely used substrates such as stainless steel plates, real substrates such as wood or gypsum board should be used for the evaluation of emissions in indoor environments.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Copenhagen : Munksgaard International Publishers
    Indoor air 12 (2002), S. 0 
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 1600-0668
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Architecture, Civil Engineering, Surveying , Medicine
    Notes: Abstract Experiments were conducted to evaluate the survival time of randomly selected female D. farinae exposed to temperatures from 40 to 80°C and relative humidities (RHs) between 10 and 90%. Significant temperature effects were found on the length of time mites can survive under those conditions. The time needed to induce 100% mortality for female D. farinae held at 40°C varied between 39 and 84 h. At 70 and 80°C, all mites died within 5 minutes. At 50°C and above, RH had little influence and temperature alone was the determining factor for mite survival. The length of survival time decreased precipitously between 40 and 50°C, suggesting that a loss of physiological integrity of female D. farinae probably occurred in this range. The results of this study indicated that the technique of raising temperatures to above 40°C for a short duration can be used to reduce living house dust mite populations in homes significantly.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...