ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 1
    Publication Date: 2020-10-09
    Description: Vortex generation and flow disruption in heat exchanger passages by means of surface modification is a widely used passive heat transfer augmentation technique. The present paper contains the results of numerical and experimental studies of the hydraulic resistance and heat transfer in the rectangle duct with oval-trench- and oval-arc-shaped dimples applied to the heat transfer surface. For the turbulent flow in the duct (Pr = 0.71, Red = 3200–9 × 104—for heat transfer determination and Red = 500–104—for the friction factor measurements), rational geometrical parameters of the oval-trench dimple were determined: relative elongation of dimple l/b = 5.57–6.78 and relative depth l/b = 5.57–6.78, while the value of the attack angle to the mean flow was fixed φ = (45–60)°. The comparison of the experimental and numerical modeling for the flow in the narrow duct over the surface with a single- and multi-row dimple arrangement has revealed a good agreement. It was found that the average heat transfer coefficient magnitudes in such ducts could be increased 1.5–2.5 times by means of single and multi-row dimple application on the heat transfer surface. The heat transfer augmentation for the surfaces with the oval-arched dimples was found to be 10% greater than the one for the oval-trench dimples. The corresponding friction factor augmentation was found to be 125–300% in comparison to the smooth surface duct. The obtained experimental data were used for the data generalization. Derived generalized equation allows for predicting the friction factor and heat transfer coefficient values for the flow over the single-row oval-trench simple arrangement. The maximal deviation of the experimental data from the proposed equations was found to be 20%. The application of the artificial neural networks for predicting the hydraulic resistance and heat transfer augmentation in such ducts was presented.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2021-10-26
    Description: The numerical simulation approach of heat carrier mixing regimes in the T-junction shows that the RANS approach is beneficial for a qualitative flow analysis to obtain relatively agreed averaged velocity and temperature. Moreover, traditionally, the RANS approach only predicts the averaged temperature distribution. This mathematical model did not consider the temperature fluctuation variations important for the thermal fatigue task. It should also be emphasized that unlike the LES approach, the steady RANS approach cannot express a local flow structure in intense mixing zones. Nevertheless, apparently the adopted RANS approach should be used for assessing the quality of computational meshes, boundary conditions with the purpose to take LES for further numerical simulation.
    Electronic ISSN: 1996-1073
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...