A circular pole face for a sextupole magnet makes the mechanical design simple to fabricate. We have optimized the radius of the circular face to minimize the field error. We have obtained a thumb rule that the optimized radius for a sextupole should be 0.56 times the half-aperture of the magnet. © 1998 American Institute of Physics.