ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Years
  • 1
  • 2
    Publication Date: 2014-12-06
    Description: Introduction: Capillary zone electrophoresis (CZE) and measurement of total immunoglobulins (total Ig) are standard techniques for the identification and quantification of monoclonal immunoglobulins (M-Ig). Heavy/light chain (HLC) pair analysis allows discrimination between Igκ and Igλ and as a result allows measurement of both the monoclonal involved and polyclonal uninvolved HLC pair. We compared measurement of M-Ig by CZE and total Ig to HLC levels. Methods: 93 samples from 8 patients with IgA intact immunoglobulin multiple myeloma (MM) were analysed. M-Ig was measured using CZE Sebia Capillarys 2 system, total IgA (tIgA) and IgAκ and IgAλ HLC concentrations on a SPAPLUS analyser. IgA HLC levels were measured with Hevylite® and compared to published normal ranges (IgAκ (g/L): 0.57-2.08, IgAλ (g/L): 0.44-2.04, IgAκ/IgAλ: 0.78-1.94). Passing and Bablok fit analysis was used to determine correlation between the assays. Results: Measurement of the involved HLC pair (iHLC) (median: 12.45g/L; range: 0.64-44.71g/L) compared well with CZE (n=34; median: 11.04g/L; range: 1.24-37.71g/L.; y= 1.2x + -2.65, R2= 0.94). Measurement of iHLC (median: 0.88. range: 0.05-21.55g/L) also compared well with tIgA measurement (n=65 median=1.44g/L; range: 0.227-21.11g/L, y=0.85x + -0.26, R2=0.98). Percent changes in iHLC concentrations from baseline through treatment compared well with CZE (n=28; y=1.59x + 0.15 R2=0.93) and tIgA (n=57; y=1.06x + 0.01, R2=0.96). Of the 34 samples with quantifiable M-protein by CZE, 32(94%) had an abnormal HLC ratio. The two discrepant samples were follow up samples from the same patient, where HLC normalised alongside total IgA entering the normal reference range. In addition, all 15 samples (15/65; 23%) where tIgA concentration was above the normal reference range all had abnormal HLC ratios. M-Ig was not detected by CZE in 48/82 (57%) samples, 46/48 of the samples (96%) had a normalised HLC ratio. In 38/65 (58%) samples, tIgA concentrations were within the normal reference range, and 34 (90%) had a normalised HLC ratio. HLC ratio for all patient samples normalised in subsequent samples following treatment. Conclusion: The measurement of M-Ig is comparable between Hevylite® and both CZE and tIgA. The presented data indicate that Hevylite® is a more sensitive test for detecting residual disease and warrants prospective studies on larger cohorts of patients. Acknowledgments:This work was partially supported by the National Science Fund (D02-35/2009). Disclosures Guenova: Novartis Pharma Sevices Bulgaria: Consultancy, Research Funding, Speakers Bureau; Roche Bulgaria: Consultancy, Research Funding, Speakers Bureau; Amgen Bulgaria: Consultancy, Research Funding, Speakers Bureau; Sanofi-Aventis Bulgaria: Consultancy, Research Funding, Speakers Bureau.
    Print ISSN: 0006-4971
    Electronic ISSN: 1528-0020
    Topics: Biology , Medicine
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2014-12-06
    Description: Introduction. Both reduction in M-protein and reconstitution of the immune system are associated with increased survival in multiple myeloma (MM) patients receiving an autologous stem cell transplant (ASCT). Heavy/light chain (HLC) pair analysis allows discrimination between Igκ and Igλ and as a result allows measurement of both the monoclonal involved and polyclonal uninvolved HLC pair. Abnormal HLC ratios and suppression of the uninvolved HLC pair correlate with shorter overall survival in MM patients. We evaluated HLC analysis for predicting progression free survival in MM patients receiving an ASCT. Methods. We prospectively evaluated 28 intact immunoglobulin MM (IIMM) patients (12 Female, 16 Male; 20 IgG, and 8 IgA; median age: 54 years; range 37-67 years) who received ASCT subsequent to high dose melphalan. Median follow up time from ASCT was 391 days (range: 61-603 days). Patient responses were assigned according to international response criteria guidelines prior to ASCT. Serum samples were analysed with Hevylite®, prior to ASCT (median: 2 days; range 0-77 days) and following ASCT (median: 50 days; range 22-119 days), on a SPAPLUS turbidimeter. HLC concentrations and ratios were compared to normal ranges (IgGk: 3.85-12.07 g/L; IgGl: 1.91-6.74 g/L; IgAk: 0.57-2.08 g/L; IgAλ: 0.44-2.04 g/L HLC ratio reference range: IgGk /IgGλ: 1.12-3.21; IgAk / IgAλ: 0.78-1.94). Progression free survival (PFS) was estimated by Kaplan Meier analysis and compared using a log rank test (Graphpad Prism). Results. Prior to ASCT, 1 patient achieved CR, 13 obtained VGPR, 9 obtained PR, 2 obtained (MR), 2 PD and 1 patient had no response assigned. An abnormal HLC ratio (18/28 patients) prior to ASCT was associated with significantly poorer PFS (17.1 months versus median not reached p=0.036). In comparison, achievement of ≥VGPR (14/28 patients) prior to ASCT was not associated with increased PFS (p=0.74). Addition of a normal HLC ratio to the assignment of response (in 8/14 patients achieving a ≥VGPR) added significant prognostic information and was significantly associated with improved PFS (median not reached versus 11.5 months, p=0.025). Suppression of the uninvolved HLC pair only (concentration below the normal reference range) prior to ASCT (15/28 patients) had no significant impact on PFS (p=0.32). Post-ASCT, an abnormal HLC ratio (11/28 patients) was not significantly associated with poorer PFS (p=0.18). However, suppression of the uninvolved HLC pair (6/28 patients) was significantly associated with poorer PFS (10.6 months versus median not reached p=0.013). Discussion. HLC analysis may provide early prognostic markers for PFS in MM patients receiving an ASCT. Warranting larger patient cohort studies, this preliminary data indicates that a normalised HLC ratio prior to ASCT and the absence of HLC paired suppression post-ASCT may be significant markers of improved PFS, adding prognostic information to current response criteria. Acknowledgments: This work was partially supported by the National Science Fund (D02-35/2009). Disclosures Guenova: Novartis Pharma Sevices Bulgaria: Consultancy, Research Funding, Speakers Bureau; Roche Bulgaria: Consultancy, Research Funding, Speakers Bureau; Amgen Bulgaria: Consultancy, Research Funding, Speakers Bureau; Sanofi-Aventis Bulgaria: Consultancy, Research Funding, Speakers Bureau.
    Print ISSN: 0006-4971
    Electronic ISSN: 1528-0020
    Topics: Biology , Medicine
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...