ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Collection
Language
  • 1
    Call number: MOP Per 850(40)
    In: Instruments and observing methods report
    In: WMO TD
    Type of Medium: Monograph available for loan
    Pages: 135 S.
    Series Statement: Report / Instruments and observing methods 40
    Location: MOP - must be ordered
    Branch Library: GFZ Library
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1573-8647
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    facet.materialart.
    Unknown
    PANGAEA
    In:  Marine Hydrophysical Institute, National Academy of Sciences of Ukraine
    Publication Date: 2023-12-15
    Keywords: Black Sea; CTD; CTD, pre-1978 standard (Fofonoff & Millard, 1983, UNESCO Tech Pap Marine Sci 44); CTD/Rosette; CTD-RO; Date/Time of event; DEPTH, water; Event label; Latitude of event; Longitude of event; MEDAR/MEDATLAS; Mediterranean Data Archaeology and Rescue; Mikhail Lomonosov; ML9; Pressure, water; Salinity; Temperature, water; UMUR19600020900010; UMUR19600020900020; UMUR19600020900030; UMUR19600020900040; UMUR19600020900050; UMUR19600020900060; UMUR19600020900070; UMUR19600020900080; UMUR19600020900090; UMUR19600020900100; UMUR19600020900110; UMUR19600020900120; UMUR19600020900130; UMUR19600020900140; UMUR19600020900150; UMUR19600020900160; UMUR19600020900170; UMUR19600020900180; UMUR19600020900190; UMUR19600020900200; UMUR19600020900210; UMUR19600020900220; UMUR19600020900230; UMUR19600020900240; UMUR19600020900250; UMUR19600020900260; UMUR19600020900270; UMUR19600020900280; UMUR19600020900290; UMUR19600020900300; UMUR19600020900310; UMUR19600020900320; UMUR19600020900330; UMUR19600020900340; UMUR19600020900350; UMUR19600020900360; UMUR19600020900370; UMUR19600020900380; UMUR19600020900390; UMUR19600020900400; UMUR19600020900410; UMUR19600020900420; UMUR19600020900430; UMUR19600020900440; UMUR19600020900450; UMUR19600020900460; UMUR19600020900470; UMUR19600020900480; UMUR19600020900490; UMUR19600020900500; UMUR19600020900510; UMUR19600020900520; UMUR19600020900530; UMUR19600020900540; UMUR19600020900550; UMUR19600020900560; UMUR19600020900570; UMUR19600020900580; UMUR19600020900590; UMUR19600020900600; UMUR19600020900610; UMUR19600020900620; UMUR19600020900630; UMUR19600020900640; UMUR19600020900650; UMUR19600020900660; UMUR19600020900670; UMUR19600020900680; UMUR19600020900690; UMUR19600020900700; UMUR19600020900710; UMUR19600020900720; UMUR19600020900730; UMUR19600020900740; UMUR19600020900750; UMUR19600020900760; UMUR19600020900770; UMUR19600020900780; UMUR19600020900790; UMUR19600020900800; UMUR19600020900810; UMUR19600020900820; UMUR19600020900830; UMUR19600020900840; UMUR19600020900850; UMUR19600020900860; UMUR19600020900870; UMUR19600020900880; UMUR19600020900890; UMUR19600020900900; UMUR19600020900910; UMUR19600020900920; UMUR19600020900930; UMUR19600020900940; UMUR19600020900950; UMUR19600020900960; UMUR19600020900970; UMUR19600020900980; UMUR19600020900990; UMUR19600020901000; UMUR19600020901010; UMUR19600020901020; UMUR19600020901030; UMUR19600020901040; UMUR19600020901050; UMUR19600020901060
    Type: Dataset
    Format: text/tab-separated-values, 3986 data points
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: A curvature-driven flute instability will be excited in the magnetized plasmas if the magnetic field lines curve toward the entire plasma boundary. Conditions under which it can be effectively stabilized in axisymmetric geometry have been experimentally studied in a gas-dynamic trap (GDT) at Novosibirsk. Flexible design of the experimental device and the availability of neutral beams and ion cyclotron heating enabled the pressure-weighted curvature to be varied over a wide range. The stability limits were thus measured and compared with those predicted by the modified Rosenbluth–Longmire criterion. Characteristics of unstable curvature-driven flute modes were also measured and found to conform to a theory including finite ion Larmor radius (FLR) effects. Stable operation during neutral beam injection was achieved with a cusp end cell, resulting in an increase in Te to 45 eV, limited by end losses rather than anomalous power losses.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Physics of Plasmas 6 (1999), S. 4360-4365 
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The electron energy distribution function measured at the channel exit of a small Hall-type thruster is interpreted as a beam–plasma electron distribution function with electron beam energy of several tens of electronvolts. Though unstable, the distribution function does not correspond to the completely quasilinear relaxed beam function. Comparison with the measured function in the vicinity of the channel exit shows that the electron beam energy is about 30 eV for the total voltage applied ∼200 V. The contribution of the electron beam is shown to be essential in the ionization of the working gas, even when only the single ionization processes are considered. © 1999 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1089-7674
    Source: AIP Digital Archive
    Topics: Physics
    Notes: In this paper, the observation of magnetohydrodynamic (MHD) stability limit in a fully axisymmetric gas-dynamic trap is reported. Transition through the stability boundary was studied by varying the plasma pressure in the stabilizing cusp end cell and simultaneously measuring the particle and energy lifetimes in the central cell. Energy and particle balance of the neutral beam heated plasma was measured and compared in unstable and stable regimes of operation. It was observed that if the calculations based on the energy principle predicted the plasma to be stable, experimentally measured transverse losses appeared to be smaller than the longitudinal ones. In the opposite case, the transverse losses were dominant thus indicating transition through the MHD stability boundary in the cusp-anchored gas-dynamic trap. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Journal of Applied Physics 88 (2000), S. 5334-5342 
    ISSN: 1089-7550
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The nonlinear response of ferroelectric BaxSr1−xTiO3 films to microwave electric field intensity up to ∼3×106 V/m was studied. Two techniques were used for this investigation: (i) 10 GHz pulsed power measurements, and (ii) 4 GHz intermodulation distortion (IMD) measurements. The nonlinear distortion of the resonant curve under microwave pulsed power and generation of the third-order IMD products in microwave resonators using ferroelectric film planar capacitors were measured. The use of microwave pulses and continuous signals enabled the separation of the nonlinear dielectric response from the heating response of the ferroelectric films and the microwave nonlinear parameters of the ferroelectric films to be determined. It is shown that up to a specified value of microwave voltage amplitude the nonlinear response of BaxSr1−xTiO3 film capacitors can be predicted from the small signal capacitance–voltage characteristics. Formulas to estimate power handling capability connected with the field dielectric nonlinearity and the film overheating are derived for the tunable microwave devices based on ferroelectric films. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 68 (1997), S. 1418-1422 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: The optimization results of the ion-optics system in a neutral beam injector are considered which is developed for application of beam emission spectroscopy in the TEXTOR tokamak. The injector is capable to deliver a neutral beam of at least 1 A in hydrogen and deuterium at 50 keV for a pulse length of 5 s into the plasma. The simulation results with the AXCEL code for grids of 4 mm thickness are discussed. The ion current of 2 A extracted by a multihole grid system at a current density of 120 mA/cm2 is generated by a rf driven ion source. The beamlet half angular divergence is below 0.6° for the optimized four-electrode ion optics system. The estimated temperature rise of the inertially cooled molybdenum grids with 150 holes and 58% transparency is max. 270 K and the related degradation in beam quality by thermal grid expansion is acceptable. © 1997 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 63 (1992), S. 3579-3582 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: A fast operating device for thickness measurement of transparent films has been designed and tested. Its principle of operation is based on the film reflection dependence on the laser beam incidence angle. The alteration of the incidence angle is produced by means of nonspherical optics. The single measurement time is less than 0.001 s, so this device allows the measurement of film thickness irregularities and investigation of the spreading liquid film thickness kinetics. The measurement frequency is 50 per second.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 71 (2000), S. 3728-3735 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: Low-divergent quasistationary neutral beams are often applied in modern magnetic fusion devices as a diagnostic tool providing unique information about plasma parameters. The most important requirements of these beams are sufficiently large current and energy of the particles, so that the beam can penetrate to the plasma core. Also the duration of the beams must be long enough, i.e., close to that of a plasma discharge, amounting to at least a few seconds for large fusion devices. We developed a neutral beam injector for plasma diagnostics in the tokamak TEXTOR-94 which is capable of meeting these requirements. The maximum beam energy is 50 keV and the source operated in hydrogen delivers an ion current of up to 2 A with a pulse duration of up to 4 s. The low divergent beam (∼0.5°– 0.6°) is geometrically focused 4 m downstream from the source having a 1/e width of ∼ 70 mm at the focal point. The beam can be modulated with a frequency variable up to 500 Hz. The ion source plasma is produced by a radio frequency discharge in hydrogen or helium. The ion beam is extracted by a four-grid system with 163 single holes. The measured beam parameters were compared with those predicted by simulations. © 2000 American Institute of Physics.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...