ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2017-12-01
    Print ISSN: 0960-1481
    Electronic ISSN: 1879-0682
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Published by Elsevier
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2020-04-30
    Description: Water scarcity remains the major looming challenge that is facing Jordan. Wastewater reclamation is considered as an alternative source of fresh water in semi-arid areas with water shortage or increased consumption. In the present study, the current status of wastewater reclamation and reuse in Jordan was analyzed considering 30 wastewater treatment plants (WWTPs). The assessment was based on the WWWTPs’ treatment processes in Jordan, the flowrates scale, and the effluents’ average total dissolved solid (TDS) contents. Accordingly, 60% of the WWTPs in Jordan used activated sludge as a treatment technology; 30 WWTPs were small scale (˂1 × 104 m3/day); and a total of 17.932 million m3 treated wastewater had low TDS (˂1000 ppm) that generally can be used in industries with relatively minimal cost of treatment. Moreover, the analysis classified the 26 million m3 groundwater abstraction by major industries in Jordanian governorates. The results showed that the reclaimed wastewater can fully offset the industrial demand of fresh water in Amman, Zarqa, and Aqaba governorates. Hence, the environmental assessment showed positive impacts of reclaimed wastewater reuse scenario in terms of water depletion (saving of 72.55 million m3 groundwater per year) and climate change (17.683 million kg CO2Eq reduction). The energy recovery assessment in the small- and medium-scale WWTPs (˂10 × 104 m3/day) revealed that generation of electricity by anaerobic sludge digestion equates potentially to an offset of 0.11–0.53 kWh/m3. Finally, several barriers and prospects were put forth to help the stakeholders when considering entering into an agreement to supply and/or reuse reclaimed water.
    Electronic ISSN: 2073-4441
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
  • 4
    Publication Date: 2020-08-10
    Description: Photovoltaic (PV) panels installation has become one of the major technologies used for energy production worldwide. Knowledge and competitive prices are the main reasons for the spread usage and expanded exploiting of PV systems. Accordingly, this creates several challenges for manufacturers and customers, mainly, the quality of PV panels to withstand environmental conditions during service lifetime. Hence, the quality of PV panels is a vital aspect. By thinking of PV power plants, it appears that some factors should be considered, like the developing microcracks (µcracks). An issue like that increases the chances of having power loss during the operation phase. Notably, µcracks develop in different shapes and orientations; the variation depends on what causes them. This study is a presentation and summary of data collected from different projects in Jordan to describe the effect of each µcracks shape on power loss, aiming to give decision makers an indication to decide whether to replace the faulty panels or not, depending on their own conditions and projects sizes. Hence, in this study, it was found that the µcracks have impacted power loss differently and recorded power reduction of percentages of 0.82–3.21% for poly-crystalline technology. Variation in power degradation depends on the module situation; whether it is stocked in facility or operated on-site. In the mono-crystalline technology case, the power losses varied between 0.55% and 0.9%, with the exception of some samples from both technologies that have effects other than microcracks, which affected power severely. Furthermore, a general overview is provided for µcracks before installation.
    Electronic ISSN: 2071-1050
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2020-05-11
    Description: Periodic daily fluctuating demand for energy and power is a perceptible phenomenon, resulting in some moments of low demand for power and energy related to the huge energy comes from renewable energy systems, and some moments of peak load demand. This phenomenon, when combined with the non-stationary operation of huge capacity of renewable energy systems, results in no stability of voltage and frequency. To assure continuous network stability and to avoid energy losses from renewable energy systems that are subject to such control system, a hybrid system with energy–power storage in the form of pumped-hydro storage is considered the most suitable technically. This paper presents the design, modeling, analysis, and feasibility study of a hybrid wind and water-pumping storage system. The system was designed and analyzed for King Talal Dam (KTD), which is in Northern Jordan. The importance of this study is that it is directed mainly to Jordan and the Middle East and North Africa (MENA) region in general. The Jordanian renewable energy market is a promising arena that encourages developers, investors, engineers, and companies to develop and install pure renewable energy systems and renewable energy hybrid projects for the generation of electricity. The analysis of wind data is carried out using the “windfarm” software with 5.16 m/s as average wind speed. It is followed by the design of the hybrid system, which is simulated for a daily operation of 2–3 h as peak load hours. Based on the technical outcomes, cost study and feasibility analyses are carried out with Jordanian market prices. The total estimated annual energy production is 26,663,933 kWh from 10 MW wind farm and 5.2 MW pumping storage system. The aforementioned studies showed that a similar hybrid system is not always fully commercially feasible. However, a pure pumped-storage system proved to be technically feasible and assisting the grid. The whole project analysis determines that such a system boosts the operational stability of the grid, increases the penetration of renewable energy systems and reduces the energy import. In addition, 15,100,000 tons of CO2-equivalent is estimated as annual emissions reduction in this study.
    Electronic ISSN: 2076-3417
    Topics: Natural Sciences in General
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2020-03-22
    Description: Brackish water desalination is widely used to supply fresh water; reverse osmosis (RO) desalination units are considered as the most widespread technology used for this purpose due to the advantage of low power consumption. On the other hand, renewable energy resource integration into the power systems is an important trend, which serves energy supply especially in rural areas and non-stable power supply places. RO units powered from Photovoltaic (PV) systems are considered one of the reliable solutions in places where both water and energy demands are issues to be improved. In this research, the idea of storing energy in water salinity is introduced and discussed to reduce conventional battery storage banks. This concept depends on changing the pressure of the RO unit based on solar profiles to get high distilled water at high solar radiation times (high pressure applied) and low distilled water at low radiation times (low pressure values). Then, the produced water is mixed to get an acceptable salinity in the produced water. This research was applied on a small-scale RO testing unit with a pressure that changed from 40 to 60 bar, and, as a result, the water conductivity changed from 1.7 to 1.1 mS/cm. This was the base line to investigate the possibility of curtailing the battery storage system of the selected plant. Following the variable pressure scenarios, energy storage capacity was reduced by a factor of 20%.
    Electronic ISSN: 2076-3417
    Topics: Natural Sciences in General
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2020-04-01
    Description: Air conditioning is becoming increasingly important in the energy supply of buildings worldwide. There has been a dramatic increase in energy requirements for cooling buildings in the Middle East and North Africa (MENA) region. This is before taking the effects of climate change into account, which will also entail a sharp increase in cooling requirements. This paper presents the potential of using a solar thermal absorption cooling system in Sub-Mediterranean Climate. Four sites in Jordan are now equipped with water-lithium bromide (H₂O-LiBr) absorption chillers with a total nominal capacity of 530 kW. The focus of the paper was on the pilot system at the German Jordanian University (GJU) campus with a cooling capacity of 160 kW. The system was designed and integrated in order to support two existing conventional compression chillers with a nominal cooling capacity of 700 kW. The system was economically evaluated based on the observed cooling capacity results with a Coefficient of Performance (COP) equals 0.32, and compared with the values observed for a COP of 0.79 which is claimed by the manufacturer. Several techniques were implemented to evaluate the overall economic viability in-depth such as present worth value, internal rate of return, payback period, and levelized cost of electricity. The aforementioned economic studies showed that the absorption cooling system is deemed not feasible for the observed COP of 0.32 over a lifespan of 25 years. The net present value was equal to −137,684 JD and a payback period of 44 years which exceeds the expected lifespan of the project. Even for an optimal operation of COP = 0.79, the discounted payback period was equal to 23 years and the Levelized Cost of Electricity (LCOE) was equal to 0.65 JD/kWh. The survey shows that there are several weaknesses for applying solar thermal cooling in developing countries such as the high cost of these systems and, more significantly, the lack of experience for such systems.
    Electronic ISSN: 2076-3417
    Topics: Natural Sciences in General
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-12-28
    Description: Desert coolers have attracted much attention as an alternative to mechanical air conditioning systems, as they are proving to be of lower initial cost and significantly lower operating cost. However, the uncontrolled increase in the moisture content of the supply air is still a great issue for indoor air quality and human thermal comfort concerns. This paper represents an experimental and numerical investigation of a modified desert air cooler into a liquid desiccant air conditioner (LDAC). An experimental setup was established to explore the supply air properties for an adapted commercial desert cooler. Several experiments were performed for air–water and air–desiccant as flow media, at several solutions to air mass ratios. Furthermore, the experimental results were compared with the result of a numerical simplified effectiveness model. The outcomes indicate a sharp reduction in the air humidity ratio by applying the desiccant solutions up to 5.57 g/kg and up to 4.15 g/kg, corresponding to dew point temperatures of 9.5 °C and 12.4 °C for LiCl and CaCl2, respectively. Additionally, the experimental and the numerical results concurred having shown the same pattern, with a maximal deviation of about 18% within the experimental uncertainties.
    Electronic ISSN: 2073-4433
    Topics: Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-11-18
    Description: To tackle climate change and secure energy supplies, many countries invest heavily on wind energy as it is a clean source and is becoming more cost effective with the technological advancement and increased capacity per unit installed. The investigation of the availability of wind resources is an essential step of any feasibility study of a wind farm project and is vital for securing financial resources. With this intent, the main aspects for designing a wind farm at Ajloun (north of Jordan) is investigated and wind energy potential is determined based on available wind data. Based on the site characteristic, the required infrastructure is highlighted, including the turbine array layout and the pattern of connections with the external transmission lines. The investigation of the feasibility of the project includes an appraisal of social and environmental consequences of constructing the wind farm project. The results show that the selected location for the wind farm is encouraging and has a promising profit potential. The findings estimate the annual electricity generation of the wind farm at 379659.51 MWh, with a breakeven selling point of around $30.03/MWh, at a highly competitive price. However, with an estimated selling price of $36.65/MWh on average, it will settle the interest rate demanded by the banks that have an internal rate of return of 7%. No major issues with geotechnical and environmental issues were identified with respect to the project.
    Print ISSN: 1748-1317
    Electronic ISSN: 1748-1325
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2020-01-20
    Description: Securing energy supply and diversifying the energy sources is one of the main goals of energy strategy for most countries. Due to climate change, wind energy is becoming increasingly important as a method of CO2-free energy generation. In this paper, a wind farm with five turbines located in Jerash, a city in northern Jordan, has been designed and analyzed. Optimization of wind farms is an important factor in the design stage to minimize the cost of wind energy to become more competitive and economically attractive. The analyses have been carried out using the WindFarm software to examine the significance of wind turbines’ layouts (M, straight and arch shapes) and spacing on the final energy yield. In this research, arranging the turbines facing the main wind direction with five times rotor diameter distance between each turbine has been simulated, and has resulted in 22.75, 22.87 and 21.997 GWh/year for the M shape, Straight line and Arch shape, respectively. Whereas, reducing the distance between turbines to 2.5 times of the rotor diameter (D) resulted in a reduction of the wind farm energy yield to 22.68, 21.498 and 21.5463 GWh/year for the M shape, Straight line and Arch shape, respectively. The energetic efficiency gain for the optimized wind turbines compared to the modeled layouts regarding the distances between the wind turbines. The energetic efficiency gain has been in the range between 8.9% for 5D (rotor diameter) straight layout to 15.9% for 2.5D straight layout.
    Electronic ISSN: 2073-4433
    Topics: Geosciences
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...