ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • equation of state  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Pure and applied geophysics 141 (1993), S. 379-392 
    ISSN: 1420-9136
    Keywords: Elastic constant ; thermodynamics ; equation of state ; acoustic velocity ; thermal expansivity ; heat capacity ; Grüneisen constant ; high pressure ; high temperature
    Source: Springer Online Journal Archives 1860-2000
    Topics: Geosciences , Physics
    Notes: Abstract The complete travel-time equation of state (CT-EOS) is presented by utilizing thermodynamics relations, such as; $$K_T = K_S (1 + \alpha \gamma T)^{ - 1} , \gamma = \frac{{\alpha K_S }}{{\rho C_P }}, \left. {\frac{{\partial C_P }}{{\partial P}}} \right)_T = - \frac{T}{\rho }\left[ {\alpha ^2 + \left. {\frac{{\partial \alpha }}{{\partial T}}} \right)_P } \right], etc.$$ The CT-EOS enables us to analyze ultrasonic experimental data under simultaneous high pressure and high temperature without introducing any assumption, as long as the density, or thermal expansivity, and heat capacity are also available as functions of temperature at zero pressure. The performance of the CT-EOS was examined by using synthesized travel-time data with random noise of 10−5 and 10−4 amplitude up to 4 GPa and 1500 K. Those test conditions are to be met with the newly developed GHz interferometry in a gas medium piston cylinder apparatus. The results suggest that the combination of the CT-EOS and accurate experimental data (10−4 in travel time) can determine thermodynamic and elastic parameters, as well as their derivatives with unprecedented accuracy, yielding second-order pressure derivatives (∂2 M/∂P 2) of the elastic moduli as well as the temperature derivatives of their first-order pressure derivatives ∂2 M/∂P∂T). The completeness of the CT-EOS provides an unambiguous criterion to evaluate the compatibility of empirical EOS with experimental data. Furthermore because of this completeness, it offers the possibility of a new and absolute pressure calibration when X-ray (i.e., volume) measurements are made simultaneously with the travel-time measurements.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...