    ISSN: 1612-1112
    Keywords: Trace organics ; Aqueous solutions ; Concentration ; Thermal desorption
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A novel technique for the analysis of volatile trace organics in aqueous solutions has been developed. Concentration of organics is performed by passage of the solution being analysed through uncoated hydrophobic capillaries as previously reported. The concentrated organics are then thermally desorbed into a cold trap and subsequently analysed by gas chromatography. The water vapor being coeluted during desorption is selectively removed by the use of a membrane dryer. Quantitative analysis of trace organics in aqueous samples has been successfully carried out in this manner.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Concentration effects ; Uncoated capillary columns ; Trace organics ; Large aqueous volumes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new technique has been developed for the concentration of organics in aqueous solutions. Volumes greater than 100 ml can be utilized in this system, which previously could not have been done without a distillation or solvent extraction procedure. The method is based on the passage of the solution through uncoated capillary columns of various materials such as polyethylene, copper, aluminum, nickel, and many other metal and/or polymer columns of different dimensions. It is possible to achieve trace level analysis at the ppb to ppt level without the interferences inherent in other existing methods. The purification of solvents has been successfully demonstrated in this preliminary study, and will be discussed along with our suggestions for future investigations.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 497-500 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; On-column injection ; Solvent polarity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 370-374 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Trace analysis ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Large sample volume on-column injection (up to 250 μL) of n-pentane solutions of halogenated hydrocarbons has been employed for the direct measurement of both low-boiling and high-boiling compounds in what is essentially a single run. Two-bonded phase, fused-silica capillary columns are joined in series, through which the low-boiling compounds are first chromatographed and detected with an electron capture detector. High-boiling compounds are then trapped in a section joining the two columns, and subsequently chromatographed in the second column, using the same detector. This procedure permits analysis at the ppt level.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 203-204 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; Photoionization detector ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 471-479 
    ISSN: 0935-6304
    Keywords: Capillary gas chromatography ; On-column injection ; Split sampling ; Temperature control ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The effect of sample injection temperature on quantitation is examined for on-column and conventional split modes of sampling in capillary gas chromatography. Discrimination effects can be observed even with on-column injection if the injection temperature is too far above the boiling point of the solvent (or that of a major low boiling constituent(. This is attributed to higher boiling components being left behind in the syringe needle, and a set of simulation experiments are described to illustrate this effect. Various discrimination patterns using conventional split injection were observed, depending on temperature of injection. Apart from syringe needle effects, discrimination is probably due to the preferential venting of higher boiling components as liquid sample droplets, which can have a lifetime greater than the time of transit to the splitter. With such a two-phase system, involving variable droplet size, the flow distribution in the splitter will be critical to uniform sampling. The use of combination on-column/split sampling, with the appropriate temperature control to provide sample uniformity to the splitter is discussed as an advantageous alternative to conventional split sampling.
    Additional Material: 7 Ill.