ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 29 (1991), S. 905-909 
    ISSN: 0887-624X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: New transparent flexible hybrid network “ceramer” materials have been synthesized by incorporating triethoxysilane capped polytetramethylene oxide with highly reactive titanium isopropoxide or zirconium n-propoxide without adding chelating agents. Both of these types of ceramer materials display high transparency while the zirconium systems show considerable transparency in the UV region. The titanium systems exhibit higher refractive index than the corresponding zirconium materials of equal alkoxide content.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 45 (1992), S. 1367-1382 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The use of functional azo initiators and the thermal history of the materials have been shown to exert significant effects on the properties of interpenetrating polymer networks (IPNs). The IPNs prepared with a reactive azo initiator from MDI and 1,2-PBD (1,2-polybutadiene diol) with PMMA have been found to exhibit greater ductility, lower rigidity, and lower moduli than IPNs prepared with AIBN. This probably resulted from the attached PMMA blocks modifying the properties of the PU matrix phases. Increasing thermal treatment of IPNs prepared from either the reactive or the normal azo initiators exhibited increased Tg values in both DSC and DMTA scans. These results have been explained by increased association from chemical reactions between the hard segments of the polyurethane and poly(methyl methacrylate) ester groups.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 36 (1997), S. 39-48 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: An intramedullary implant model in the canine femora was developed to evaluate the mechanical and histological responses between cancellous bone and plasma-sprayed hydroxyapatite coatings (HACs) on Ti-6A1-4V implants, with 12- and 24-week follow-ups. HACs of different thicknesses were investigated. Results of the mechanical testings revealed that after 24 weeks of implantation, the mean shear strength (2.49 ± 0.12 MPa) of the 50 μm HACs was significantly higher (p 〈 0.05) than that of the 200 μm HACs (1.44 ± 0.19 MPa). However, using backscattered electron images (BEIs) throughout all the implant periods, no substantial histological variations in the extent of new bone apposition between the two HACs were observed. Occasionally, solution-mediated disintegration of the 50 μm HAC was found 24 weeks postimplantation. Histomorphometric studies from the BEIs demonstrated that for both HACs the percentage of the direct HAC-cancellous bone contact was approximately 50% at 12 weeks and 75% at 24 weeks. After the mechanical tests, the 200 μm HACs had fracture sites either inside the coating layers or at the HAC-titanium interfaces, which might explain why the mechanical performance of the 200 μm HACs was inferior to that of the 50 μm HACs even though both HACs had the same histological behaviors. © 1997 John Wiley & Sons, Inc.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 29 (1995), S. 1483-1492 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: With three kinds of plasma-sprayed hydroxyapatite coatings (HACs) prepared, the objectives of this study were (1) to establish the calibration methods for quantitatively measuring the concentration of impurity phases and the degree of crystallinity of the HACs, and (2) to explore the effects of postheat treatments at various temperatures in vacuo on the changes of phases and crystallinity of the HACs. By the internal standard method used, the concentrations of impurity phases, such as α-TCP, β-TCP, and TP, of the assprayed HACs were significantly higher than those measured by the direct intensity-ratio method, and the CaO phase was lower than the direct intensity-ratio method. When the HACs were heat treated in the temperature interval 630-850°C, the concentrations of impurity phases obviously decreased, and the coating crystallinity apparently increased. After annealing at 850°C, an HAC consisting of at least 95% crystallinity with few impurity phases was obtained. As the annealing temperatures in the interval 850-1000°C were applied, however, the HA phase seriously decomposed, resulting in the appearance of a large number (higher than 20 wt%) of impurity phases in the HACs. This work suggests that the optimum heat treatment conditions in vacuo for maximizing crystallinity and minimizing impurity phases of the HACs do not occur at the same temperature. © 1995 John Wiley & Sons, Inc.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 27 (1993), S. 1315-1327 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Plasma-sprayed hydroxyapatite coated (HAC) 50 and 200 μm thick on Ti-6Al-4v cylinders was transcortically implanted in the femora of canines to to evaluate in detail the effect of coating thickness on the pushout shear strength and failure mode examined under scanning electron microscope after the periods of 4, 6, 8, and 12 weeks. The HAC coating exhibited higher shear strength at 50 μm than at 200 μm. Its failure mode was conclusively at or near the HAC-bone interface, and the slight attack of body fluid had not degraded the implant to the extent that failure occurred at the HAC-Ti alloy interface after 12 weeks of observation. For 200 μm-HAC, failure was found at the HAC-bone interface, inside the HAC lamellar splat layer and at the HAC-Ti alloy substrate interface, depending on the period of implantation. It was also deduced that the variation of failure mode of 200 μm-HAC with time could not be accounted for by the attack of body fluid alone; the degradation must be a synergetic adverse result of residual stress in the HAC and the attack of body fluid. © 1993 John Wiley & Sons, Inc.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 0021-9304
    Keywords: bonding-strength ; shear-strength ; simulated body fluid ; push-out measurement ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurity-phases, and indices-of-crystallinity were used. In vitro testings were done by measuring the bonding-strength at the Ti-6Al-4V-HAC interface, with HACs that had and had not been immersed in a pH-buffered, serum-added simulated body fluid (SBF). The shear-strength at the HAC-bone interface was investigated in a canine transcortical femoral model after 12 and 24 weeks of implantation. The results showed a bonding degradation of approximately 32% or higher of the original strength after 4 weeks of immersion in SBF, and this predominantly depended on the constructed microstructure of the HACs. After the push-out measurements, it was demonstrated that the HACs with higher bonding-strength in vitro would correspondingly result in significantly higher shear-strength at each implant period in vivo. Nevertheless, there were no substantial histological variations between the two types of HACs evaluated. The most important point elucidated in this study was that, among coating characteristics, the microstructure was the key factor in influencing the mechanical stability of the HACs both in vitro and in vivo. As a consequence, a denser HAC was needed to ensure mechanical stability at both interfaces. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 335-345, 1997.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...