ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Microbore columns ; Column-switching ; Myristicin ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A microbore high-performance liquid chromatographic method with column-switching was developed for the analysis of myristicin from rat serum without prepurification. Deproteinization, fractionation, concentration and separation of analyte were carried out by appropriate switching of columns and using solvent mixtures. The method showed excellent precision, accuracy and speed with a detection limit of 10 ng mL−1 from 25 μL of serum. The total analysis time per sample was 25 min and the coefficients of variation for intra- and inter-assay were less than 1.8%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Column-switching ; Parathion, and metabolites in serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new high-performance liquid chromatographic method with column-switching has been developed for the simultaneous determination of parathion and its metabolites such asp-nitrophenol and paraoxon in serum. Serum samples were injected onto a precolumn packed with LiChroprep RP-8 after simple dilution with 20% phosphoric acid. Polar plasma components were washed with 0.02 M phosphate buffer (pH 3.0). After valve switching, the concentrated compounds were eluted in back-flush mode and separated on a Ultracarb ODS 30 column with a gradient of acetonitrile −0.01 M phosphate buffer (pH 3.0) as mobile phase. The method showed excellent precision, accuracy and speed with detection limit of 0.1 μg mL−1. Total analysis time per sample was 〈40 min and coefficients of variation for intra-and inter-assay were 〈4.5%.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2019-06-28
    Description: A method has been studied for predicting the acoustic field of the SR-3 transonic propfan using flow data generated by two versions of the NASPROP-E computer code. Since the flow fields calculated by the solvers include the shock-wave system of the propeller, the nonlinear quadrupole noise source term is included along with the monopole and dipole noise sources in the calculation of the acoustic near field. Acoustic time histories in the near field are determined by transforming the azimuthal coordinate in the rotating, blade-fixed coordinate system to the time coordinate in a nonrotating coordinate system. Fourier analysis of the pressure time histories is used to obtain the frequency spectra of the near-field noise.
    Keywords: ACOUSTICS
    Type: AIAA PAPER 89-1040
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...