ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • 42.60.Fc  (1)
  • Root/solution ratio  (1)
  • Springer  (2)
  • Institute of Physics
  • 1
    ISSN: 1432-0630
    Keywords: 42.60.Fc ; 61.30 ; 68.15
    Source: Springer Online Journal Archives 1860-2000
    Topics: Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Abstract By irradiation of the tunneling junction of a scanning tunneling microscope with intensity-modulated laser light a gap-width modulation due to thermal expansion of tip and sample was produced. Photothermal images were obtained by spatial mapping of the resulting modulation of the tunneling current or its logarithm. The various mechanisms responsible for the observed contrast are discussed quantitatively. In case of a highly corrugated gold film on mica the contrast arises mainly from either the current variations caused by the non-zero reaction time of the current control loop or from a geometry factor. In both cases the images reflect certain properties of the sample topography. On the other hand, for a liquid-crystal film adsorbed on graphite a contrast on a molecular scale was found which is attributed to variations of the effective barrier height.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Plant and soil 68 (1982), S. 135-138 
    ISSN: 1573-5036
    Keywords: Ammonium acetate ; CEC ; Immersion time ; Root/solution ratio
    Source: Springer Online Journal Archives 1860-2000
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition
    Notes: Summary A rapid exchange procedure using ammonium acetate as an extractant was developed for measurement of cation exchange capacity (CEC) of plant roots. The CEC values obtained with 1∶100 and 1∶200 root/solution ratios were almost equal, though the values increased with length of the time of immersion in both the root/solution ratios. The method gave higher CEC values with fresh roots as compared to dried roots. However, dried milled and dried unmilled roots gave identical values.
    Type of Medium: Electronic Resource
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...