ALBERT

All Library Books, journals and Electronic Records Telegrafenberg

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2004-07-23
    Print ISSN: 0967-3334
    Electronic ISSN: 1361-6579
    Topics: Medicine , Physics
    Published by Institute of Physics
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2011-08-24
    Description: The effects of brief but repeated bouts of micro- and hypergravity on cerebrovascular responses to head-up tilt (HUT) were examined in 13 individuals after (compared to before) parabolic flight. Middle cerebral artery mean flow velocity (MCA MFV; transcranial Doppler ultrasound), eye level blood pressure (BP) and end tidal CO(2) (P(ET)CO(2)) were measured while supine and during 80 degrees HUT for 30 min or until presyncope. In the postflight tests subjects were classified as being orthostatically tolerant (OT) (n = 7) or intolerant (OI) (n = 6). BP was diminished with HUT in the OT group in both tests (p 〈 0.05) whereas postflight BP was not different from supine in the OI group. Postflight compared to preflight, the reduction in P(ET)CO(2) with HUT (p 〈 0.05) increased in both groups, although significantly so only in the OI group (p 〈 0.05). The OI group also had a significant decrease in supine MCA MFV postflight (p 〈 0.05) that was unaccompanied by a change in supine P(ET)CO(2). The decrease in MCA MFV that occurred during HUT in both groups preflight (p 〈 0.05) was accentuated only in the OI group postflight, particularly during the final 30 s of HUT (p 〈 0.05). However, this accentuated decrease in MCA MFV was not correlated to the greater decrease in P(ET)CO(2) during the same period (R = 0.20, p = 0.42). Although cerebral vascular resistance (CVR) also increased in the OI group during the last 30 s of HUT postflight (p 〈 0.05), the dynamic autoregulatory gain was not simultaneously changed. Therefore, we conclude that in the OI individuals, parabolic flight was associated with cerebral hypoperfusion following a paradoxical augmentation of CVR by a mechanism that was not related to changes in autoregulation nor strictly to changes in P(ET)CO(2).
    Keywords: Aerospace Medicine
    Type: Brain research bulletin (ISSN 0361-9230); Volume 53; 1; 113-20
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 3
    Publication Date: 2011-08-24
    Description: Because it is not clear that the induction of orthostatic intolerance in returning astronauts always requires prolonged exposure to microgravity, we investigated orthostatic tolerance and autonomic cardiovascular function in 16 healthy subjects before and after the brief micro- and hypergravity of parabolic flight. Concomitantly, we investigated the effect of parabolic flight-induced vomiting on orthostatic tolerance, R-wave-R-wave interval and arterial pressure power spectra, and carotid-cardiac baroreflex and Valsalva responses. After parabolic flight 1) 8 of 16 subjects could not tolerate 30 min of upright tilt (compared to 2 of 16 before flight); 2) 6 of 16 subjects vomited; 3) new intolerance to upright tilt was associated with exaggerated falls in total peripheral resistance, whereas vomiting was associated with increased R-wave-R-wave interval variability and carotid-cardiac baroreflex responsiveness; and 4) the proximate mode of new orthostatic failure differed in subjects who did and did not vomit, with vomiters experiencing comparatively isolated upright hypocapnia and cerebral vasoconstriction and nonvomiters experiencing signs and symptoms reminiscent of the clinical postural tachycardia syndrome. Results suggest, first, that syndromes of orthostatic intolerance resembling those developing after space flight can develop after a brief (i.e., 2-h) parabolic flight and, second, that recent vomiting can influence the results of tests of autonomic cardiovascular function commonly utilized in returning astronauts.
    Keywords: Aerospace Medicine
    Type: Journal of applied physiology (Bethesda, Md. : 1985) (ISSN 8750-7587); Volume 90; 1; 67-82
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 4
    Publication Date: 2011-08-24
    Description: We examined the effects of 30 min of exposure to either +3GX (front-to-back) or +GZ (head-to-foot) centrifugation on cerebrovascular responses to 80 degrees head-up tilt (HUT) in 14 healthy individuals. Both before and after +3 GX or +3 GZ centrifugation, eye-level blood pressure (BP(eye)), end tidal PCO2 (PET(CO2)), mean cerebral flow velocity (CFV) in the middle cerebral artery (transcranial Doppler ultrasound), cerebral vascular resistance (CVR), and dynamic cerebral autoregulatory gain (GAIN) were measured with subjects in the supine position and during subsequent 80 degrees HUT for 30 min. Mean BP(eye) decreased with HUT in both the GX (n = 7) and GZ (n = 7) groups (P 〈 0.001), with the decrease being greater after centrifugation only in the GZ group (P 〈 0.05). PET(CO2) also decreased with HUT in both groups (P 〈 0.01), but the absolute level of decrease was unaffected by centrifugation. CFV decreased during HUT more significantly after centrifugation than before centrifugation in both groups (P 〈 0.02). However, these greater decreases were not associated with greater increases in CVR. In the supine position after centrifugation compared with before centrifugation, GAIN increased in both groups (P 〈 0.05, suggesting an autoregulatory deficit), with the change being correlated to a measure of otolith function (the linear vestibulo-ocular reflex) in the GX group (r = 0.76, P 〈 0.05) but not in the GZ group (r = 0.24, P = 0.60). However, GAIN was subsequently restored to precentrifugation levels during postcentrifugation HUT (i.e., as BP(eye) decreased), suggesting that both types of centrifugation resulted in a leftward shift of the cerebral autoregulation curve. We speculate that this leftward shift may have been due to vestibular activation (especially during +GX) or potentially to an adaptation to reduced cerebral perfusion pressure during +GZ.
    Keywords: Aerospace Medicine
    Type: Journal of applied physiology (Bethesda, Md. : 1985) (ISSN 8750-7587); Volume 91; 5; 1986-94
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 5
    Publication Date: 2018-06-11
    Description: To identify accurate predictors for the risk of sudden death in patients with familial dysautonomia (FD). Ten-minute resting high-fidelity 12-lead ECGs were obtained from 14 FD patients and 14 age/gender-matched healthy subjects. Multiple conventional and advanced ECG parameters were studied for their ability to predict sudden death in FD over a subsequent 4.5-year period, including multiple indices of linear and non-linear heart rate variability (HRV); QT variability; waveform complexity; high frequency QRS; and derived Frank-lead parameters. Four of the 14 FD patients died suddenly during the follow-up period, usually with concomitant pulmonary disorder. The presence of low vagally-mediated HRV was the ECG finding most predictive of sudden death. Concomitant left ventricular hypertrophy and other ECG abnormalities such as increased QTc and JTc intervals, spatial QRS-T angles, T-wave complexity, and QT variability were also present in FD patients, suggesting that structural heart disease is fairly common in FD. Although excessive or unopposed cardiac vagal (relative to sympathetic) activity has been postulated as a contributor to sudden death in FD, the presence of low vagally-mediated HRV was paradoxically the best predictor of sudden death. However, we suggest that low vagally-mediated HRV be construed not as a direct cause of sudden death in FD, but rather as an effect of concurrent pathological processes, especially hypoxia due to pulmonary disorders and sleep apnea, that themselves increase the risk of sudden death in FD and simultaneously diminish HRV. We speculate that adenosine may play a role in sudden death in FD, possibly independently of vagal activity, and that adenosine inhibitors such as theophylline might therefore be useful as prophylaxis in this disorder.
    Keywords: Life Sciences (General)
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 6
    Publication Date: 2019-07-13
    Description: We have developed a dry-electrode harness that permits easy, rapid, and unsupervised self-acquisition of resting 12-lead ECGs without the use of any disposables. Various other advantageous features of the harness include: 1) padded or inflatable cushions at the lateral sides of the torso that function to press the left arm (LA) and right arm (RA) dry electrodes mounted on cushions against sideward (as shown in the Figure below) or downward-rested arms of the subject; 2) sufficient distal placement of the arm electrodes with good abutment and without the need for adhesives, straps, bands, bracelets, or gloves on the arms; 3) padding over the sternum to avoid "tenting" in the V1 through V3 (and V3R, when present) electrode positions; 4) easy-to-don, one-piece design with an adjustable single point of connection and an adjustable shoulder strap; and 5) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar lead placements.
    Keywords: Man/System Technology and Life Support
    Type: JSC-CN-25230 , 2012 NASA Human Research Program Investigators'' Workshop; Feb 14, 2012 - Feb 16, 2012; Houston, TX; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 7
    Publication Date: 2019-07-13
    Description: INTRODUCTION: Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. PURPOSE: The purpose of this study was to deploy and then evaluate the contribution of resting advanced ECG (A-ECG) in addition to other screening tools (family history, lipid profiles, and cardiopulmonary exercise tests, XT) in assessment of an individual fs cardiac risk profile. METHODS: Forty-four career firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance, fasting lipids and glucose. Five-min resting 12-lead A-ECGs were obtained in a subset of firefighters (n=21) and transmitted over a secure networked system to a NASA physician collaborator. Using myocardial perfusion and other imaging as the gold standard, A-ECG scoring has been proven useful in accurately identifying a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, and non-ischemic and ischemic cardiomyopathy. RESULTS: Subjects f mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI 28 (3) kg/m2. Fifty-one percent of subjects had .3 cardiovascular risk factors. One subject had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data.
    Keywords: Life Sciences (General)
    Type: JSC-CN-25097 , 59th American College of Sports Medicine Annual meeting; May 29, 2012 - Jun 02, 2012; San Francisco, CA; United States
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 8
    Publication Date: 2019-07-19
    Description: Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (〈50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also 〉100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (〉100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P 〈 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P 〈 0.05), whereas mean HF QRS amplitude was decreased significantly (P 〈 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P 〈 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.
    Keywords: Aerospace Medicine
    Type: JSC-CN-23515 , Congress of the European College of Veterinary Internal Medicine; Sep 08, 2011 - Sep 10, 2011; Sevilla; Spain
    Format: application/pdf
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 9
    Publication Date: 2019-07-19
    Description: We investigated fluid shifts and regulatory responses to variations of posture, exercise, Gz level and radius of rotation in subjects riding NASA Ames 20G centrifuge. Results are from 4 protocols that address radius and exercise effects only. Protocol A: After 10 min supine control, 12 healthy men (35 plus or minus 9 yr, 82.8 plus or minus 7.9 kg) were exposed to rotational 1 Gz (2.5 m radius) for 2 min followed by 20 min alternating between 1 and 1.25 Gz. Blood samples were taken pre and post spin. Protocol B: Same as A, but lower limb exercise (70% V02max) preceded ramps to 1.25 Gz. Protocol C: Same as A but radius of rotation 8.3 m. Protocol D: Same as B but at 8.3 m. The 8 subjects who completed all protocols, increased heart rate (HR) from control, on average, by: A: 5, B: 39, C: 11, D: 44 bpm. For thoracic fluid volume, (bioimpedance), the 8 subjects changed from control, on average: A: -394, B: -548, C: -537, D: -708 mL. For thigh fluid volume, changes from control, on average, were: A: -137, B: 129, C: -75, D: 159 mL. Hematocrit changes from control were: A: 2.3, B: 3.5, C: 2.3, D: 4.3 %. Radius effects were mild and included greater loss of fluid from the thorax, less fluid loss from the thigh and increased heart rate at the longer radius. Pre-acceleration exercise effects were more dramatic and included additional loss of fluid from the chest, increased fluid volume of the thigh, increased hematocrit and greater heart rate increases. We propose that short bouts of intense exercise can be used to magnify the cardiovascular stress delivered by artificial gravity (AG) training and the combination of AG with exercise training can be fine-tuned to preserve orthostatic tolerance of astronauts during spaceflight.
    Keywords: Life Sciences (General)
    Type: 29th Annual ISGP Meeting: Life in Space for Life on Earth; Jun 22, 2008 - Jun 27, 2008; Angers; France
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
  • 10
    Publication Date: 2019-07-19
    Description: We investigated the ability of beat-to-beat QT interval variability (QTV) and related parameters to differentiate healthy individuals from patients with obstructive coronary artery disease (CAD) and cardiomyopathy (CM). For this purpose we developed a PC-based ECG software program that in real time, acquires, analyzes and displays QTV in each of the eight independent channels that constitute the 12-lead conventional ECG. The system also analyzes and displays the QTV from QT interval signals that are derived from multiple channels and from singular value decomposition (SVD) to substantially reduce the effect of noise and other artifacts on the QTV results. It also provides other useful SVD-related parameters such as the normalized 3-dimensional volume of the T wave (nTV) = 100*(rho(sub 2)*rho(sub 3)rho(sub 1^2). Advanced high-fidelity 12-lead ECG tests (approx. 5-min supine) were first performed on a "training set" of 99 individuals: 33 with ischemic or dilated CM and low ejection fraction (EF less than 40%); 33 with catheterization-proven obstructive CAD but normal EF; and 33 age-/gender-matched healthy controls. All QTV parameters that were studied for their accuracy in detecting CM and CAD significantly differentiated both CM and CAD from controls (p less than 0.0001). Retrospective areas under the ROC curve (AUC) of SDNN-QTV, rmsSD-QTV, and QTV Index (QTVI) for CM vs. controls in the lead V5 were 0.85, 0.90, and 0.99, respectively, and those for CAD vs. controls in the lead II were 0.82, 0.82, and 0.89. Other advanced ECG parameters, such as HFQRS RAZ score, LF Lomb of RRV or QRS-T angle, differentiated both CM and CAD from controls less significantly, with the respective AUC values of 0.89, 0.88 and 0.98 for CM vs. controls, and 0.73, 0.71 and 0.80 for CAD vs. controls. QTV parameters (especially QTVI, which is QTV as indexed to RRV) were, diagnostically speaking, amongst the best performing of the advanced ECG techniques studied thus far.
    Keywords: Life Sciences (General)
    Type: Computers in Cardiology; Sep 30, 2007 - Oct 03, 2007; Durham, NC; United States
    Format: text
    Location Call Number Expected Availability
    BibTip Others were also interested in ...
Close ⊗